How to go from 3 to 2 phase with the Decanter Centrifuge with the kit?
If your Decanter Centrifuge was ordered with a special kit, it can be changed from 2 to 3 phases and vice versa
From 3 to 2 phases
1. Replace the oil levels with the plugs; ensure that there are O-rings on the plugs
2.Remove weir plates
3.Turn the screw inside the bowl until the holes in the weir plate line up with the square plugs on the locking flange inside the bowl.
4. Remove the four square plugs on the locking plate. Screw a threaded rod over the hole on the square plug in order to hold it
5. Replace the old weir plates with the new ones
From 2 to 3 phases
1.
Remove the weir plates
2. Turn the screw inside the bowl until the holes in the weir plate line up with the square holes on the locking flange inside the bowl.
3.Remove the four square plugs on the locking plate. Screw a threaded rod over the hole on the square plug in order to hold it
4.Replace the new weir plates with the old ones
5. Replace the oil plugs with the oil levels; ensure that there are o-rings on the oil levels
Related Articles
How does 3 phase Decanter Centrifuge work?
Three Phase Decanter Centrifuge Decanter 3 Phase is typically used to separate oil, water and solids. In these designs the cake is separated and removed as in the two-phase design. Inlet sludge, through feed pipe, will be conducted inside bowl of ...
What does a Centrifuge skid look like
Skid Our Hybridec Decanter Centrifuge Systems are always available as a pre-built, pre-piped and tested skid Benefits Hydrostatically tested Fully piped, wired, engineered and tested prior to shipment Fully Assembled: All connections on a simple ...
How to Remotely Control Centrifuge
Remote Connection In order to satisfy customer’s necessities and in order to help at the best on the resolution of possible issues, it is possible to activate two different systems for the remote connection: VNC and VPN. The first one allows to ...
What Quality Standards apply to your Decanter Centrifuges?
Applicable standards to Decanter construction - ISO 9001:2015 Quality Management System - ISO 10204:2004 Metallic products. Types of inspection documents - IEC 60034-1 for electrical motors (EU) - CSA/UL / NEMA ...
How to determine motor speed on Centrifuge
Look at the VFD display for main motor. Read the running Hz From motor nameplate find the RPM corresponding to 60Hz installation Scale RPM over 60Hz and find your current RPM based on the Running Hz example: 3600rpm 60Hz = 60rpm/Hz = 1HZ=60rpm ...