How to determine clearance between scroll and bowl
DR100/CD10 to DR450/CD45 is 1mm
DR500/CD50 to DR800/CD80 is 1.5mm
Related Articles
How to find weight of Bowl & Scroll Rotating Assembly for transport and lifting
The weights per model are: DR800 - Complete rotor (bowl, screw)= 4315kg - Complete rotor, front support and rear support = 4895kg (4315kg, 290kg, 290kg) - Complete rotor, front support and rear support, gearbox = 5555kg ...
How to determine motor speed on Centrifuge
Look at the VFD display for main motor. Read the running Hz From motor nameplate find the RPM corresponding to 60Hz installation Scale RPM over 60Hz and find your current RPM based on the Running Hz example: 3600rpm 60Hz = 60rpm/Hz = 1HZ=60rpm ...
How to remove the rotating assembly from the centrifuge
Important Before commencing the work to replace the bearing, make sure that the machine is off and put in the safety position(control panel is not powered). To lift out the rotating assembly, in order to for example replace the bearings, loosen the ...
What is your largest municipal centrifuge installation?
The Sudbury, Ontario Wastewater Treatment Plant features two Hybricecs with our 30" bowl diameter machines
How to go from 3 to 2 phase with the Decanter Centrifuge with the kit?
If your Decanter Centrifuge was ordered with a special kit, it can be changed from 2 to 3 phases and vice versa From 3 to 2 phases 1. Replace the oil levels with the plugs; ensure that there are O-rings on the plugs 2.Remove weir plates ...