How to schedule maintenance on my centrifuge

How to schedule maintenance on my centrifuge

Maintenance Component

Maintenance

Task

Interval

Duration

Transmission belt

Check belt tension

Every 800-1000 working hours

30min.

Replace belt

Every 10000 working hours

2 hours

Bearing

Grease

Every 100 working hours

15min.

Check integrity

Every 2500 working hours

5min

Replace

Every 5000 working hours

8 hours, recommended by factory technician

Scraper grease

Grease

Every 100 working hours

Included with bearing greasing time

Manual cleaning

Every 500 working hours

15 min.

Hydraulic oil

Check oil level

Every 100 working hours

1 min. visual inspection

Replace

The first time 1500 hours Every 3000 working hours

15min.

Hydraulic oil filter

Replace

First time 500 hours then Every 1500 hours thereafter

40 min.

Cyclo gearbox

Top up Oil

As oil level alarm is reach on HMI

15 min.

Replace seal

Every 5000 working hours

1-2 hours, recommended by factory technician

Bowl + Scraper

Visual inspection of the outside of the bowl and scraper gear.

Every 1000 working hours

20 min.

Discharge bushing

Check wear

Every 1000 working hours

15 min.

Replace

Every 5000 working hours

1 hour.

Pump flange

Replace

Every 5000 working hours

1-2 hours, recommended by factory technician


    • Related Articles

    • What does a Centrifuge skid look like

      Skid Our Hybridec Decanter Centrifuge Systems are always available as a pre-built, pre-piped and tested skid Benefits Hydrostatically tested Fully piped, wired, engineered and tested prior to shipment Fully Assembled: All connections on a simple ...
    • How does 3 phase Decanter Centrifuge work?

      Three Phase Decanter Centrifuge Decanter 3 Phase is typically used to separate oil, water and solids. In these designs the cake is separated and removed as in the two-phase design.   Inlet sludge, through feed pipe, will be conducted inside bowl of ...
    • Scrudrain O&M Schedule

      Frequency O&M TASK DESCRIPTION TIME TO COMPLETE Every Working Day Verify that the washing system operates properly 2 min. Every 500 hours Grease Bearing 1 min. Every 5 years Replace Bearing 2 hours Replace Belt Every 5-7 years 1 day
    • How to go from 3 to 2 phase with the Decanter Centrifuge with the kit?

      If your Decanter Centrifuge was ordered with a special kit, it can be changed from 2 to 3 phases and vice versa From 3 to 2 phases 1.         Replace the oil levels with the plugs; ensure that there are O-rings on the plugs 2.Remove weir plates ...
    • How to Remotely Control Centrifuge

      Remote Connection In order to satisfy customer’s necessities and in order to help at the best on the resolution of possible issues, it is possible to activate two different systems for the remote connection: VNC and VPN. The first one allows to ...