Recent Articles
How to Select a flowmeter
Flowmeter selection must consider a few parameters. Siemens has an excellent guide on liner and electrode selection, which is attached to this article. Power Supply The power supply voltage which can be 24VDC/24VAC or 120VAC. The simplest is to use ...
Scrudrain O&M Schedule
Frequency O&M TASK DESCRIPTION TIME TO COMPLETE Every Working Day Verify that the washing system operates properly 2 min. Every 500 hours Grease Bearing 1 min. Every 5 years Replace Bearing 2 hours Replace Belt Every 5-7 years 1 day
How to Replace Spiral on Sedigrit
Replacement of Sedigrit Screw Empty the machine by running on screw on manual and opening the drain at bottom of unit. Disconnect motor from main supply Remove the covers; To follow the correct order of cover removal see the images below. 1.REMOVE ...
How to Replace Perfordrum wheels
FIRST THING: SAFETY. SHUT DOWN THE POWER. REF. Serial 2388 1ST STEP: UNBOLT TANK CONVERS AND REMOVE THEM 2ND STEP: UNSCREW THE THREE SCREWS ON BOTH SIDES OF THE TANK 3RD STEP: HOOK THE TWO LIFTING POINTS TO CHAINS IN ORDER TO LIFT THEM UP. SUPPORT ...
How to resolve Oil Cooling Alarm
If you cannot reset the alarm after letting the machine rest and reset, then you can perform these troubleshooting steps. Check physical condition If you have an oil cooling alarm you must verify and ensure that there is no physical reason; such as ...